TMA TECHNICAL DATA

Technical Data

Model
TMA

Heat rejection kW (*)

Air flow m3/s

No. of fans
and motors
T = transmission

Power of each motor
KW

 

Model
TMA

Heat rejection
KW (*)

Air flow m3/s

No. of fans
and motors
T = transmission

Power of each motor kW

08-55

547

10.36

1

4

 

34-434S

4344

88.33

3T

3 x 11

08-58

580

10.36

1

4

 

34-497

4971

93.33

3

3 x 15

08-67

673

11.25

1

5.5

 

34-537

5376

95.83

3

3 x 18.5

08-76

756

13.33

1

5.5

 

34-537S

5376

95.83

3T

3 x 18.5

08-84

840

15

1

7.5

 

19-195

1951

36.39

1

18.5

08-90

897

15.56

1

11

 

19-211

2112

37.5

1

22

08-96

955

17.78

1

7.5

 

19-211S

2112

37.5

1T

18.5

08-103

1036

19.44

1

11

 

29-390

3902

72.78

2

2 x 18.5

08-109

1092

19.44

1

11

 

29-422

4224

75

2

2 x 22

11-131

1309

26.39

1

11

 

29-422S

4224

75

2T

2 x 18.5

11-145

1450

27.22

1

15

 

19-189S

1895

47.22

1T

15

11-153

1529

27.22

1

15

 

19-248

2488

50.14

1T

22

20-191/CT

1910

35.56

2

2 x 7.5

 

19-260

2600

48.75

1T

22

20-207/CT

2072

38.89

2

2 x 11

 

19-288

2888

51.5

1T

30

20-219/CT

2184

38.89

2

2 x 11

 

29-498

4976

100.28

2T

2 x 22

21-261/CT

2618

52.78

2

2 x 11

 

29-520

5200

97.5

2T

2 x 22

21-276/CT

2762

54.44

2

2 x 15

 

29-577

5776

103

2T

2 x 30

21-291/CT

2912

54.44

2

2 x 15

 

19-218S

2187

53.33

1T

18.5

31-392/CT

3927

79.17

3

3 x 11

 

19-262S

2625

53.33

1T

22

31-435/CT

4350

81.67

3

3 x 15

 

19-300

3004

56.39

1T

30

31-458/CT

4586

81.67

3

3 x 15

 

19-316

3167

56.39

1T

30

14-145S

1448

29.44

1T

11

 

29-525S

5250

106.67

2T

2 x 22

14-166

1657

31.11

1

15

 

29-600

6008

112.78

2T

2 x 30

14-179

1792

31.94

1

18.5

 

29-633

6334

112.78

2T

2 x 30

14-179S

1792

31.94

1T

18.5

 

39-746

7464

150.42

3T

3 x 22

24-289S

2896

58.89

2T

2 x 11

 

39-780

7800

146.25

3T

3 x 30

24-331

3314

62.22

2

2 x 15

 

39-866

8664

169.27

3T

3 x 30

24-358

3584

63.89

2

2 x 18.5

 

 

 

 

 

 

24-258S

3584

63.89

2T

2 x 18.5

 

 

 

 

 

 

 

The maximum water temperature on to standard towers must not exceed 80°C

(*) Nominal heat rejection at the following conditions:  wet bulb 24°C / water inlet 35°C / water outlet 30°C

  1. Models with the suffix ‘CT’ are container compatible, but are not necessarily the most economical selection.
  2. Models with the suffix ‘S’ have a lower noise level with a similar capacity, but are more expensive.